The Sinocare Safe AQ Air Blood Glucose Monitor combines precision and smart technology for effortless glucose monitoring. This compact device delivers fast, accurate readings in seconds, perfect for daily diabetes management. With seamless Bluetooth connectivity, it syncs easily with your devices for convenient health tracking. Suitable for both personal and professional use, it’s a reliable, user-friendly solution for confident diabetes care.
₨750
The Safe AQ Air Glucometer utilises the most advanced enzyme technology available in the glucose monitoring market: GDH-FAD (FAD-GDH). This enzyme effectively eliminates interference from 74 endogenous and exogenous substances, including simple sugars (such as maltose, galactose, and fructose) and common medications (such as ampicillin, penicillin, ibuprofen, and ascorbic acid).
Additionally, the Safe AQ Air Glucometer’s innovative enzyme technology allows for testing not only with fingerstick blood samples but also with blood drawn from alternative sites (AST) and even venous blood samples. This versatility makes the Safe AQ Air Glucometer suitable for hospital use, where it can serve as a primary diagnostic tool in clinical settings.
The 10 records of Safe-AQ machine can not be deleted at the same time. Once 10 records are in memory, adding a new record causes the oldest one to be deleted. The records can be covered but can not be deleted all.
There are four main reasons will cause this error message ,such as incorrect test method,used test strip ,expired test strip or damped test strip ,test strip exposed to air more than 3 minutes.
If so,you need to use a new test strip and insert test strips into meter before apply sample to strips then test again
Besides,you need to confirm you purchased the correspond test strips with your glucometer at the same time.
Test strips are available in pharmacies and medical shops.(Please note to buy safe AQ smart test strips)
Yes, you can use the glucometer to test the blood sugar for others, please notice the lancets and strips are for one-time use.
Hello, please follow the below steps and try again:
When taking blood, you need to wait for the alcohol to evaporate before giving the needle injection.
Yes, it will record the results of your previous measurements.
Please replace the battery (confirm the batteries are correctly installed with the right position of sign “+” and “-”)and insert the test strip, the meter will turn on automatically in most cases.
No, you can't. It's just for one-time use.
No, they do not. Safe AQ Air test strips can only be used with Sinocare Safe AQ Air blood glucose monitor, and it can not work with devices in other brands.
Code-free strips are already ready to use out-of-the-box, while with the non-coded ones, you have to enter a code into the glucometer.
Please put the item in the top pull back at the bottom twice and then push the release to stab the finger you need the maximum gear. If this doesn’t work yet, it may be defective.
Set number 4 if your finger’s skin is soft, and higher if it’s thick or calloused. If you’ve just started, try a couple of different settings to find the most suitable numbers for you. You don't need a lot of blood but a clear drop seems to be sucked more easily than blood that's spread.
Please twist the adjustable comfort tip to adjust the puncture depth.If your finger skin is thin and soft, you can set a lower gear of the lancet pen.
All of our lancets lengths are the same as yours.
You can twist the adjustable comfort tip to adjust the puncture depth.
When you replace the end cap, you shouldn't see the lancet and that's for the safety of the customer.
And when you apply a blood sample, you need to place the tip firmly against the finger with the other hand, and then press the trigger button, so the lancet will trigger quickly to puncture your finger tip."